STANDARDIZED SANITATION SYSTEMS, INC. -- TAURUS,SE -- 7930-00F031113
=====================  Product Identification  =====================

Product ID:TAURUS,SE
MSDS Date:07/01/1986
FSC:7930
NIIN:00F031113
=== Responsible Party ===
Company Name:STANDARDIZED SANITATION SYSTEMS, INC.
Address:141 MIDDLESEX TURNPIKE
City:BURLINGTON
State:MA
ZIP:01803
Country:US
Info Phone Num:617-273-2020
Emergency Phone Num:617-273-2020
CAGE:SSSYS
=== Contractor Identification ===
Company Name:STANDARDIZED SANITATION SYSTEMS INC
Address:141 MIDDLESEX TURNPIKE
City:BURLINGTON
State:MA
ZIP:01803-4493
Country:US
Phone:800-228-5535; 617-273-2020
CAGE:SSSYS

=============  Composition/Information on Ingredients  =============

Ingred Name:SODIUM HYDROXIDE, CAUSTIC SODA, LYE
CAS:1310-73-2
RTECS #:WB4900000
Fraction by Wt: <10%
Other REC Limits:2MG/M3 CEILING NIOSH
OSHA PEL:2 MG/CUM
ACGIH TLV:2 MG/CUM CEILING
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:2-AMINOETHANOL, ETHANOLAMINE, MONOETHANOLAMINE
CAS:141-43-5
RTECS #:KJ5775000
Fraction by Wt: <20%
Other REC Limits:3 PPM
OSHA PEL:3 PPM
ACGIH TLV:7.5 MG/CUM

Ingred Name:WEIGHT PER GALLON IN POUNDS: 8.76
RTECS #:9999999WG

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:CORROSIVE MATERIAL. EYES: CORNEAL
    DAMAGE & BURNS. INGESTION: BURNS TO MUCOUS MEMBRANES/INTERNAL
    DAMAGE & POSSIBLY DEATH. INHALATION: MISTS OR VAPORS CAN CAUSE
    DAMAGE TO UPPER RESPIRATORY TRACT & LUNG  TISSUE. SKIN: BURNS.
    PROLONGED CONTACT MAY RESULT IN ABSORPTION IN POTENTIALLY HARMFUL
    AMOUNTS.
Explanation of Carcinogenicity:NONE
Medical Cond Aggravated by Exposure:DERMATITIS

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH W/WATER FOR AT LEAST 15 MINS. SKIN: WASH AFFECTED
    AREAS W/LARGE AMOUNTS OF SOAP & WATER. INGESTION: DON'T INDUCE
    VOMITING. DILUTE BY DRINKING WATER. INHALATION: REMOVE TO FRESH
    AIR. IF NEC ESSARY, GIVE CPR OR OXYGEN. NEVER ANYTHING BY MOUTH IF
    UNCONSCIOUS. OBTAIN MEDICAL ATTENTION IN ALL CASES.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:>200F
Extinguishing Media:DRY CHEMICAL, CO2, ALCOHOL-TYPE OR ALL-PURPOSE TYPE
    FOAMS FOR LARGE FIRES
Fire Fighting Procedures:WEAR SCBA W/FULL PROTECTIVE EQUIPMENT. DON'T
    USE WATER STREAMS, MAY CAUSE FROTHINGS & INCREASE FIRE INTENSITY.

==================  Accidental Release Measures  ==================

Spill Release Procedures:STOP SPILL AT SOURCE. PREVENT RUN OFF. MOP,
    SHOVEL, PUMP, & ABSORB W/INERT MATERIAL & PLACE IN SOUND
    CONTAINERS. RINSE REMAINING RESIDUE W/EXCESS WATER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:WARNING: CORROSIVE LIQUID. HANDLE ALL
    CONTAINERS CAREFULLY.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:AS REQUIRED.
Ventilation:MECHANICAL: TO KEEP VAPOR CONCENTRATION BELOW TLV.
Protective Gloves:RUBBER/POLYVINYL CHLORINATED
Eye Protection:SAFETY GLASSES/GOGGLES
Other Protective Equipment:NORMAL WORK CLOTHING COVERING ARMS & LEGS &
    IMPERVIOUS BOOTS
Supplemental Safety and Health
AVAILABLE IN 1 GAL, 5 GAL, & 55 GAL CONTAINERS. THIS MATERIAL IS 100%
    BIODEGRADEABLE. VISCOSITY: <2 CP (CENTIPOISES, 23C). HARD WATER
    TOLERANCE: (HARDNESS AS CALCIUM CARBONATE): 2000 PPM.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:212F
Spec Gravity:1.045-1.055
pH: 12.9
Evaporation Rate & Reference:AS WATER
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR COLORLESS LIQUID W/LEMON ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ACIDS, OXIDIZERS
Stability Condition to Avoid:TEMPS <32F & >120F
Hazardous Decomposition Products:CO, CO2, NITROGEN OXIDES

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN APPROVED WASTE FACILITY ACCORDING
    TO LOCAL, STATE, & FEDERAL REGULATIONS. CORROSIVE LIQUID.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their