REYNOLDS METAL CO -- GRANULAR POWDER, LSB-468 -- 6810-00N027592
=====================  Product Identification  =====================

Product ID:GRANULAR POWDER, LSB-468
MSDS Date:12/07/1987
FSC:6810
NIIN:00N027592
=== Responsible Party ===
Company Name:REYNOLDS METAL CO
Address:6601 BROAD STREET RD
City:RICHMOND
State:VA
ZIP:23230
Country:US
Info Phone Num:804-281-2000
Emergency Phone Num:804-281-2000
CAGE:77783
=== Contractor Identification ===
Company Name:REYNOLDS METAL CO
Address:6601 BROAD STREET RD
Box:City:RICHMOND
State:VA
ZIP:23230
Country:US
Phone:804-281-2000
CAGE:77783

=============  Composition/Information on Ingredients  =============

Ingred Name:ING 8:DUST-LADEN CLOUD/CAUSE POWDER TO DISPERSE IN AIR. SEE
    NFPA#651. IF VACUUM CLEANER IS USED, ITS PIPING, (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:SUCTION HOSE & TOOLS SHOULD BE ELECTRICALLY
    CONDUCTIVE & SHOULD BE GROUND TO PVNT STATIC ELEC SPARKS. (ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10:SEE NFPA#77. ONLY VACUUM CLEANERS SPECIFICALLY
    APPRVD FOR USE W/REACTIVE COMBUST METAL SHOULD BE USED. (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11:(STD COMMERCIAL INDUST VACUUM CLEANERS SHOULD NOT BE
    USED, AS THEY ARE NOT SAFE W/COMBUST METALS). (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12: VACUUM SYSTEM'S ELECTRICAL EQUIPMENT SHOULD BE
    SUITABLE FOR CLASS II, GROUP E LOCATION.
RTECS #:9999999ZZ

Ingred Name:ALUMINUM. MP: 1453F, 789C
CAS:7429-90-5
RTECS #:BD0330000
Fraction by Wt: >95%
OSHA PEL:15MG/M3 DUST/5 FUME
ACGIH TLV:10MG/M3 DUST/5 FUME

Ingred Name:SILICON
CAS:7440-21-3
RTECS #:VW0400000
Fraction by Wt: <1.0%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9293

Ingred Name:IRON
CAS:7439-89-6
RTECS #:NO4565500
Fraction by Wt: <1.0%
OSHA PEL:10 MG/M3 FUME(OXIDE)
ACGIH TLV:5 MG/M3 FUME(OXIDE)

Ingred Name:MANGANESE
CAS:7439-96-5
RTECS #:OO9275000
Fraction by Wt: <1.0%
OSHA PEL:(C) 5 MG/M3 DUST
ACGIH TLV:5 MG/M3 DUST 9293

Ingred Name:MAGNESIUM
CAS:7439-95-4
RTECS #:OM2100000
Fraction by Wt: <1.8%

Ingred Name:COPPER
CAS:7440-50-8
RTECS #:GL5325000
Fraction by Wt: <4.9%
OSHA PEL:0.1MG/M3 FUME/1 DUST
ACGIH TLV:0.2MG/M3 FUME/1 DUST
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:ZINC. PEL: 10 MG/M3 DUST, 5 FUME (OXIDE). TLV: 10 MG/M3
    DUST, 5 FUME (OXIDE)
CAS:7440-66-6
RTECS #:ZG8600000
Fraction by Wt: <1.0%
OSHA PEL:INGRED NAME
ACGIH TLV:INGRED NAME
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:SPILL PROC: USED, BECAUSE OF THEIR TENDENCY TO ACCUMULATE
    STRONG STATIC CHARGES. AVOID ACTION THAT WOULD CREATE (ING 9)
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:HIGH EXPOSURES TO ALUMINUM POWDER MAY
    PRODUCE IRRITATION OF EYES AND RESPIRATORY SYSTEM.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:IRRITATION OF EYES AND RESPIRATORY TRACT.
Medical Cond Aggravated by Exposure:PRE-EXISTING UPPER RESPIRATORY AND
    LUNG DISEASES SUCH AS, BUT NOT LIMITED TO, BRONCHITIS, EMPHYSEMA,
    AND ASTHMA.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MIN TO REMOVE
    PARTICLES. SEEK MED ATTN. SKIN: FLUSH WITH COPIOUS AMOUNTS OF
    WATER. CALL MD . INHAL: REMOVE TO FRESH AIR. SUPPORT BRTHG. (GIVE
    O*2/ARTF RESP ) . INGEST: CALL MD .

=====================  Fire Fighting Measures  =====================

Lower Limits:40%
Extinguishing Media:HALOGENATED EXTING AGENTS (SUCH AS HALON) SHOULD
    NOT BE USED. TO CTRL SPREAD OF FIRE, DO NOT USE H*2O; RING (SUPP
    DATA)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:ALUMINUM DUST MAY BE IGNITED BY STATIC
    DISCHARE & BURN @ EXTREMELY HIGH TEMP. IN BULK FORM, IT IS IGNITED
    BY STATIC DISCHARGE W/DFCLTG; HOWEVER, (SUPP DATA)

==================  Accidental Release Measures  ==================

Spill Release Procedures:ALL SPILLS SHOULD FIRST BE CLEANED BY SCOOP &
    MILD BRUSH. CLEAN SHOULD BE DONE W/SOFT BRUSH/SPONGE, & PICKUP
    SHOULD BE W/NON-SPARK CONDUCTIVE SCOOPS. SNYTHETIC FIBER BRISTLE
    BRUSH & PLASTIC, OR OTHER  NONCONDUCTIVE SCOOPS SHOULD NOT BE  (ING
    8)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:FOR MORE DETAILED INFO REFER TO
    ALUMINUM ASSOC BULLETIN TR-2,  RECOM FOR STORAGE & HNDLG OF
    ALUMINUM PIGMENTS & POWDERS'.
Other Precautions:SHIPMENTS OF PRODUCT MUST BE IN COMPLIANCE WITH ALL
    APPLICABLE STATE, FEDERAL AND INTERNATIONAL TRANSPORTATION
    REGULATIONS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF TLVS OR PELS ARE EXCEEDED, USE NIOSH/MSHA
    APPROVED PARTICULATE RESPIRATOR.
Ventilation:LOC EXHAUST IF TLVS OR PELS ARE EXCEEDED. NOTE: SEE CAUTION
    CONCERNING EXPLOSION HAZARD OF DUST.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES.
Other Protective Equipment:NONE.
Work Hygienic Practices:USE APPROPRIATE WORK PRACTICES TO MAINTAIN
    EXPOSURE BELOW TLVS AND PELS.
Supplemental Safety and Health
EXTING MEDIA:FIRES W/DRY SAND, USING NON-SPARK SHOVELS; AVOID CREATING
    DUST CLOUDS, ELIMINATE DRAFTS, LET FIRE EXTING ITSELF. EXPLO
    HAZ:ONCE SUSPENDED IN DUST-LADEN AIR CLOUD, IT IS READILY IGNITED &
     VERY EXPLO. ALUMINUM DUST IS EXPLO OVERFAIRLY WIDE RANGE OF LOAD
    DPNG ON PARTICLE SIZE, SURF AREA, & OTHER FACTORS.

==================  Physical/Chemical Properties  ==================

HCC:N1
Melt/Freeze Pt:M.P/F.P Text:SEE ING 1
Spec Gravity:2.7
Solubility in Water:INSOLUBLE
Appearance and Odor:ODORLESS GRAY SILVER POWDER.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
H*2O, MINERAL ACIDS HARSH ALKALIS, & HALOGENATED CMPDS. SEE NFPA#491M,
    FOR SPEC INCOMPAT MATL.
Stability Condition to Avoid:IMPROPER STORAGE WHICH WOULD ALLOW
    INTRODUCTION OF WATER AND/OR FOREIGN MATTER.
Hazardous Decomposition Products:NONE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:FOR DISPOSAL OF MATERIAL AS WASTE, ACT IN
    ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL WASTE
    MANAGEMENT REGULATIOINS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.